O P E R A T I N G I N S T R U C T I O N S Select-A-Charge Battery Chargers models: SCP, SCPX, SCS, SCSX, SCX For Indu
When powered up the LED is solid red with a yellow flash, and displaying 02. The battery is very low, and the charger is in a slow charge phase until
The cycle ends with Er showing, and a green/yellow flashing LED. An incomplete cycle. The batteries did not reach minimum voltage requirements, and th
QUICK CHARGE Select-a-Charge Battery Chargers “LIMITED WARRANTY” Quick Charge Corporation warrants this line of chargers for
If your charger is programmed for Lithium Ion batteries the display will read “FC” Final Charge instead of 80% To discontinue charging,
SAFETY INFORMATION AC WIRING: Before making AC connections, refer to the requirements on the charger ID label. If your charger is not equipped with a
OTHER SAFETY INFORMATION Do not use charger if it shows signs of physical stress, or if DC output leads or connector feel hot when used. Do not disco
failure. Re-charge batteries as soon as possible after a deep discharge, but not if they are warm, allow a cooling down period. Provide adequate v
REPROGRAMMING There are 5 charge profiles, and 5 programming adjustments that can be made to the profiles. The profiles are: F1 is a single stage f
r1 when set to the F2 profile, charge will terminate, and the battery will be checked weekly, if the voltage falls to a predetermined level, the charg
TROUBLESHOOTING Symptom Cause Corrective Action When plugged into AC power the LED flashes red/green, and a 0 on display. Connected reverse to bat